{"title":"Humidity Control","description":"\u003cp\u003eWithin a building automation network there are many different components for the measurement, detection, and control of humidity. These products deliver real-time data to the BAS system for precise RH management. We offer humidity sensors, detectors, transmitters, and controllers from trusted brands including Johnson Controls, Senva, Greystone Energy, and Siemens.\u003c\/p\u003e","products":[{"product_id":"senva-ht1r-2aud-humidity-sensor","title":"Senva HT1R-2AUD Recessed Wall RH Sensor, 2% RH, LCD","description":"\u003cp\u003eThe Senva HT1R-2AUD is an HT1R recessed-wall humidity sensor with +\/-2% RH specified accuracy over 0-100% RH and an LCD display. No optional temperature output is selected; internal temperature compensation for RH does not add a temperature output.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148361842866,"sku":"HT1R-2AUD","price":169.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_3cb41217-783f-4dbe-af94-c3c9c960521d.jpg?v=1772681375"},{"product_id":"senva-ht1r-2aux-humidity-sensor","title":"Senva HT1R-2AUX Recessed Wall RH Sensor, 2% RH, No LCD","description":"\u003cp\u003eThe Senva HT1R-2AUX is an HT1R recessed-wall humidity sensor with +\/-2% RH specified accuracy over 0-100% RH and no LCD display. No optional temperature output is selected; internal temperature compensation for RH does not add a temperature output.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148361941170,"sku":"HT1R-2AUX","price":149.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_4a3af830-8b2c-41d6-bd1b-1d1a7ceb08a2.jpg?v=1772681375"},{"product_id":"senva-ht1r-2bud-humidity-sensor","title":"Senva HT1R-2BUD Recessed Wall RH Sensor, 2% RH, LCD, Temperature transmitter","description":"\u003cp\u003eThe Senva HT1R-2BUD is an HT1R recessed-wall humidity sensor with +\/-2% RH specified accuracy over 0-100% RH and an LCD display. This configuration includes a temperature transmitter with selectable 10-35 degrees C or 0-50 degrees C output scaling. Output scaling is not an overall operating-temperature rating.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148362072242,"sku":"HT1R-2BUD","price":183.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_7046547b-21a1-4cb3-8231-94af06ec92ab.jpg?v=1772681377"},{"product_id":"senva-ht1r-2bux-humidity-sensor","title":"Senva HT1R-2BUX Recessed Wall RH Sensor, 2% RH, No LCD, Temperature transmitter","description":"\u003cp\u003eThe Senva HT1R-2BUX is an HT1R recessed-wall humidity sensor with +\/-2% RH specified accuracy over 0-100% RH and no LCD display. This configuration includes a temperature transmitter with selectable 10-35 degrees C or 0-50 degrees C output scaling. Output scaling is not an overall operating-temperature rating.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148362137778,"sku":"HT1R-2BUX","price":162.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_ab0e1595-29c9-4bb8-9238-879a0e0fd0c7.jpg?v=1772681378"},{"product_id":"senva-ht1r-2dux-humidity-sensor","title":"Senva HT1R-2DUX Recessed Wall RH Sensor, 2% RH, No LCD, 1000 ohm platinum RTD (385)","description":"\u003cp\u003eThe Senva HT1R-2DUX is an HT1R recessed-wall humidity sensor with +\/-2% RH specified accuracy over 0-100% RH and no LCD display. This configuration includes a 1000 ohm platinum RTD (385) as its separate passive temperature option, not the temperature-transmitter option.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148362203314,"sku":"HT1R-2DUX","price":162.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_af7ca0c5-d0d4-4df0-9875-989de69714fc.jpg?v=1772681379"},{"product_id":"senva-ht1r-2eud-humidity-sensor","title":"Senva HT1R-2EUD Recessed Wall RH Sensor, 2% RH, LCD, 10K ohm Type 2 thermistor","description":"\u003cp\u003eThe Senva HT1R-2EUD is an HT1R recessed-wall humidity sensor with +\/-2% RH specified accuracy over 0-100% RH and an LCD display. This configuration includes a 10K ohm Type 2 thermistor as its separate passive temperature option, not the temperature-transmitter option.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148362498226,"sku":"HT1R-2EUD","price":183.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_9c36059e-52a1-4836-b156-b57052deaf94.jpg?v=1772681380"},{"product_id":"senva-ht1r-2eux-humidity-sensor","title":"Senva HT1R-2EUX Recessed Wall RH Sensor, 2% RH, No LCD, 10K ohm Type 2 thermistor","description":"\u003cp\u003eThe Senva HT1R-2EUX is an HT1R recessed-wall humidity sensor with +\/-2% RH specified accuracy over 0-100% RH and no LCD display. This configuration includes a 10K ohm Type 2 thermistor as its separate passive temperature option, not the temperature-transmitter option.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148364267698,"sku":"HT1R-2EUX","price":162.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_dff44fd0-e49e-43c5-b137-18b73b2aa281.jpg?v=1772681381"},{"product_id":"senva-ht1r-2fud-humidity-sensor","title":"Senva HT1R-2FUD Recessed Wall RH Sensor, 2% RH, LCD, 10K ohm Type 3 thermistor","description":"\u003cp\u003eThe Senva HT1R-2FUD is an HT1R recessed-wall humidity sensor with +\/-2% RH specified accuracy over 0-100% RH and an LCD display. This configuration includes a 10K ohm Type 3 thermistor as its separate passive temperature option, not the temperature-transmitter option.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148364366002,"sku":"HT1R-2FUD","price":183.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_0dbea186-a413-4ab8-8060-291848452fbe.jpg?v=1772681383"},{"product_id":"senva-ht1r-2fux-humidity-sensor","title":"Senva HT1R-2FUX Recessed Wall RH Sensor, 2% RH, No LCD, 10K ohm Type 3 thermistor","description":"\u003cp\u003eThe Senva HT1R-2FUX is an HT1R recessed-wall humidity sensor with +\/-2% RH specified accuracy over 0-100% RH and no LCD display. This configuration includes a 10K ohm Type 3 thermistor as its separate passive temperature option, not the temperature-transmitter option.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148364464306,"sku":"HT1R-2FUX","price":162.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_d83a1b13-cd63-48a2-b526-34af39dbc14a.jpg?v=1772681384"},{"product_id":"senva-ht1r-2gud-humidity-sensor","title":"Senva HT1R-2GUD Recessed Wall RH Sensor, 2% RH, LCD, 10K ohm Type 3 thermistor with 11K ohm shunt","description":"\u003cp\u003eThe Senva HT1R-2GUD is an HT1R recessed-wall humidity sensor with +\/-2% RH specified accuracy over 0-100% RH and an LCD display. This configuration includes a 10K ohm Type 3 thermistor with 11K ohm shunt as its separate passive temperature option, not the temperature-transmitter option.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148364595378,"sku":"HT1R-2GUD","price":183.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_23c73db4-9bc3-4632-9ace-00c22aaeb066.jpg?v=1772681385"},{"product_id":"senva-ht1r-2gux-humidity-sensor","title":"Senva HT1R-2GUX Recessed Wall RH Sensor, 2% RH, No LCD, 10K ohm Type 3 thermistor with 11K ohm shunt","description":"\u003cp\u003eThe Senva HT1R-2GUX is an HT1R recessed-wall humidity sensor with +\/-2% RH specified accuracy over 0-100% RH and no LCD display. This configuration includes a 10K ohm Type 3 thermistor with 11K ohm shunt as its separate passive temperature option, not the temperature-transmitter option.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148364693682,"sku":"HT1R-2GUX","price":162.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_2b8674fa-3112-4d53-bf1e-60415da03694.jpg?v=1772681386"},{"product_id":"senva-ht1r-2kux-humidity-sensor","title":"Senva HT1R-2KUX Recessed Wall RH Sensor, 2% RH, No LCD, 20K ohm thermistor","description":"\u003cp\u003eThe Senva HT1R-2KUX is an HT1R recessed-wall humidity sensor with +\/-2% RH specified accuracy over 0-100% RH and no LCD display. This configuration includes a 20K ohm thermistor as its separate passive temperature option, not the temperature-transmitter option.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148364955826,"sku":"HT1R-2KUX","price":162.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_b3ba1dcb-a4eb-4efd-85a7-7e5fcd08f827.jpg?v=1772681387"},{"product_id":"senva-ht1r-3aud-humidity-sensor","title":"Senva HT1R-3AUD Recessed Wall RH Sensor, 3% RH, LCD","description":"\u003cp\u003eThe Senva HT1R-3AUD is an HT1R recessed-wall humidity sensor with +\/-3% RH specified accuracy over 0-100% RH and an LCD display. No optional temperature output is selected; internal temperature compensation for RH does not add a temperature output.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148365054130,"sku":"HT1R-3AUD","price":164.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_61518a09-42c1-440b-b020-29634314b085.jpg?v=1772681389"},{"product_id":"senva-ht1r-3aux-humidity-sensor","title":"Senva HT1R-3AUX Recessed Wall RH Sensor, 3% RH, No LCD","description":"\u003cp\u003eThe Senva HT1R-3AUX is an HT1R recessed-wall humidity sensor with +\/-3% RH specified accuracy over 0-100% RH and no LCD display. No optional temperature output is selected; internal temperature compensation for RH does not add a temperature output.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148369281202,"sku":"HT1R-3AUX","price":145.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_a42a7f80-3791-4c08-810f-c35117eb4fa3.jpg?v=1772681390"},{"product_id":"senva-ht1r-3bud-humidity-sensor","title":"Senva HT1R-3BUD Recessed Wall RH Sensor, 3% RH, LCD, Temperature transmitter","description":"\u003cp\u003eThe Senva HT1R-3BUD is an HT1R recessed-wall humidity sensor with +\/-3% RH specified accuracy over 0-100% RH and an LCD display. This configuration includes a temperature transmitter with selectable 10-35 degrees C or 0-50 degrees C output scaling. Output scaling is not an overall operating-temperature rating.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148369739954,"sku":"HT1R-3BUD","price":178.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_9596ac8d-e790-4ea8-a3c4-2dcba0b06374.jpg?v=1772681391"},{"product_id":"senva-ht1r-3bux-humidity-sensor","title":"Senva HT1R-3BUX Recessed Wall RH Sensor, 3% RH, No LCD, Temperature transmitter","description":"\u003cp\u003eThe Senva HT1R-3BUX is an HT1R recessed-wall humidity sensor with +\/-3% RH specified accuracy over 0-100% RH and no LCD display. This configuration includes a temperature transmitter with selectable 10-35 degrees C or 0-50 degrees C output scaling. Output scaling is not an overall operating-temperature rating.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148369838258,"sku":"HT1R-3BUX","price":157.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_d63e097b-8b6c-4d57-9764-dccfd0e1fc8f.jpg?v=1772681392"},{"product_id":"senva-ht1r-3dux-humidity-sensor","title":"Senva HT1R-3DUX Recessed Wall RH Sensor, 3% RH, No LCD, 1000 ohm platinum RTD (385)","description":"\u003cp\u003eThe Senva HT1R-3DUX is an HT1R recessed-wall humidity sensor with +\/-3% RH specified accuracy over 0-100% RH and no LCD display. This configuration includes a 1000 ohm platinum RTD (385) as its separate passive temperature option, not the temperature-transmitter option.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148369903794,"sku":"HT1R-3DUX","price":157.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_aa1b4607-44b1-4e51-8257-fc0ff35c5527.jpg?v=1772681393"},{"product_id":"senva-ht1r-3eud-humidity-sensor","title":"Senva HT1R-3EUD Recessed Wall RH Sensor, 3% RH, LCD, 10K ohm Type 2 thermistor","description":"\u003cp\u003eThe Senva HT1R-3EUD is an HT1R recessed-wall humidity sensor with +\/-3% RH specified accuracy over 0-100% RH and an LCD display. This configuration includes a 10K ohm Type 2 thermistor as its separate passive temperature option, not the temperature-transmitter option.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148370002098,"sku":"HT1R-3EUD","price":178.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_4def744a-6fa3-49dd-a998-e5a6c1d541dc.jpg?v=1772681394"},{"product_id":"senva-ht1r-3eux-humidity-sensor","title":"Senva HT1R-3EUX Recessed Wall RH Sensor, 3% RH, No LCD, 10K ohm Type 2 thermistor","description":"\u003cp\u003eThe Senva HT1R-3EUX is an HT1R recessed-wall humidity sensor with +\/-3% RH specified accuracy over 0-100% RH and no LCD display. This configuration includes a 10K ohm Type 2 thermistor as its separate passive temperature option, not the temperature-transmitter option.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148370067634,"sku":"HT1R-3EUX","price":157.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_237809c7-4c13-4932-9e98-6d902ac1e880.jpg?v=1772681396"},{"product_id":"senva-ht1r-3fud-humidity-sensor","title":"Senva HT1R-3FUD Recessed Wall RH Sensor, 3% RH, LCD, 10K ohm Type 3 thermistor","description":"\u003cp\u003eThe Senva HT1R-3FUD is an HT1R recessed-wall humidity sensor with +\/-3% RH specified accuracy over 0-100% RH and an LCD display. This configuration includes a 10K ohm Type 3 thermistor as its separate passive temperature option, not the temperature-transmitter option.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148370395314,"sku":"HT1R-3FUD","price":178.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_82808f38-03db-4a10-9238-aeceb82e14e2.jpg?v=1772681397"},{"product_id":"senva-ht1r-3fux-humidity-sensor","title":"Senva HT1R-3FUX Recessed Wall RH Sensor, 3% RH, No LCD, 10K ohm Type 3 thermistor","description":"\u003cp\u003eThe Senva HT1R-3FUX is an HT1R recessed-wall humidity sensor with +\/-3% RH specified accuracy over 0-100% RH and no LCD display. This configuration includes a 10K ohm Type 3 thermistor as its separate passive temperature option, not the temperature-transmitter option.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148372000946,"sku":"HT1R-3FUX","price":157.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_c656bf96-f9f2-4083-802a-5b92ccf229a4.jpg?v=1772681398"},{"product_id":"senva-ht1r-3kux-humidity-sensor","title":"Senva HT1R-3KUX Recessed Wall RH Sensor, 3% RH, No LCD, 20K ohm thermistor","description":"\u003cp\u003eThe Senva HT1R-3KUX is an HT1R recessed-wall humidity sensor with +\/-3% RH specified accuracy over 0-100% RH and no LCD display. This configuration includes a 20K ohm thermistor as its separate passive temperature option, not the temperature-transmitter option.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. The datasheet lists a 12-30 VDC or 24 VAC supply, 100 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The recessed housing provides a low-profile installation without exposed screws. The PTFE media filter has IP54 protection; this is not a whole-enclosure IP54 rating.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148378652850,"sku":"HT1R-3KUX","price":157.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_ad1a76f1-cbcb-490b-abe2-249f0b27276a.jpg?v=1772681399"},{"product_id":"senva-ht1w-2aud-humidity-sensor","title":"Senva HT1W-2AUD Surface Wall RH Sensor, 2% RH, LCD","description":"\u003cp\u003eThe Senva HT1W-2AUD is an HT1W surface-wall humidity sensor with the 2% RH accuracy option and an LCD display. In the shared HT1 ordering matrix, enclosure code W identifies surface-wall mounting, distinct from the HT1R recessed-wall version.\u003c\/p\u003e\u003cp\u003eTemperature code A selects no optional temperature output. Output code U selects universal analog output: 4-20 mA, 0-5 V, or 0-10 V, with 2-wire or 3-wire connection according to the selected mode and installation instructions.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148378718386,"sku":"HT1W-2AUD","price":169.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_cc0ab911-8d10-42c5-b0de-3d79477b78a9.jpg?v=1772681401"},{"product_id":"senva-ht1w-2aux-humidity-sensor","title":"Senva HT1W-2AUX Surface Wall RH Sensor, 2% RH, No LCD","description":"\u003cp\u003eThe Senva HT1W-2AUX is an HT1W surface-wall humidity sensor with the 2% RH accuracy option and no LCD display. In the shared HT1 ordering matrix, enclosure code W identifies surface-wall mounting, distinct from the HT1R recessed-wall version.\u003c\/p\u003e\u003cp\u003eTemperature code A selects no optional temperature output. Output code U selects universal analog output: 4-20 mA, 0-5 V, or 0-10 V, with 2-wire or 3-wire connection according to the selected mode and installation instructions.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148378816690,"sku":"HT1W-2AUX","price":149.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_4ea2d6fa-07a2-4fee-bf82-152bbc26655e.jpg?v=1772681402"},{"product_id":"senva-ht1w-2bud-humidity-sensor","title":"Senva HT1W-2BUD Surface Wall RH Sensor, 2% RH, LCD, Temperature transmitter","description":"\u003cp\u003eThe Senva HT1W-2BUD is an HT1W surface-wall humidity sensor with the 2% RH accuracy option and an LCD display. In the shared HT1 ordering matrix, enclosure code W identifies surface-wall mounting, distinct from the HT1R recessed-wall version.\u003c\/p\u003e\u003cp\u003eTemperature code B selects a temperature transmitter. Output code U selects universal analog output: 4-20 mA, 0-5 V, or 0-10 V, with 2-wire or 3-wire connection according to the selected mode and installation instructions.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148378914994,"sku":"HT1W-2BUD","price":183.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_5b110a2e-49f8-449f-b187-1e4f6c9560ae.jpg?v=1772681403"},{"product_id":"senva-ht1w-2bux-humidity-sensor","title":"Senva HT1W-2BUX Surface Wall RH Sensor, 2% RH, No LCD, Temperature transmitter","description":"\u003cp\u003eThe Senva HT1W-2BUX is an HT1W surface-wall humidity sensor with the 2% RH accuracy option and no LCD display. In the shared HT1 ordering matrix, enclosure code W identifies surface-wall mounting, distinct from the HT1R recessed-wall version.\u003c\/p\u003e\u003cp\u003eTemperature code B selects a temperature transmitter. Output code U selects universal analog output: 4-20 mA, 0-5 V, or 0-10 V, with 2-wire or 3-wire connection according to the selected mode and installation instructions.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148379078834,"sku":"HT1W-2BUX","price":162.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_2ad3d89f-43ca-4d98-9a7f-7d64630ba7cf.jpg?v=1772681404"},{"product_id":"senva-ht1w-2eud-humidity-sensor","title":"Senva HT1W-2EUD Surface Wall RH Sensor, 2% RH, LCD, 10K ohm Type 2 thermistor","description":"\u003cp\u003eThe Senva HT1W-2EUD is an HT1W surface-wall humidity sensor with the 2% RH accuracy option and an LCD display. In the shared HT1 ordering matrix, enclosure code W identifies surface-wall mounting, distinct from the HT1R recessed-wall version.\u003c\/p\u003e\u003cp\u003eThe selected temperature option is a 10K ohm Type 2 thermistor, a passive element rather than a temperature transmitter. Output code U selects universal analog output: 4-20 mA, 0-5 V, or 0-10 V, with 2-wire or 3-wire connection according to the selected mode and installation instructions.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148379144370,"sku":"HT1W-2EUD","price":183.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_295ccd91-fd99-46f3-9907-55ea6a429bc2.jpg?v=1772681406"},{"product_id":"senva-ht1w-2eux-humidity-sensor","title":"Senva HT1W-2EUX Surface Wall RH Sensor, 2% RH, No LCD, 10K ohm Type 2 thermistor","description":"\u003cp\u003eThe Senva HT1W-2EUX is an HT1W surface-wall humidity sensor with the 2% RH accuracy option and no LCD display. In the shared HT1 ordering matrix, enclosure code W identifies surface-wall mounting, distinct from the HT1R recessed-wall version.\u003c\/p\u003e\u003cp\u003eThe selected temperature option is a 10K ohm Type 2 thermistor, a passive element rather than a temperature transmitter. Output code U selects universal analog output: 4-20 mA, 0-5 V, or 0-10 V, with 2-wire or 3-wire connection according to the selected mode and installation instructions.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148379308210,"sku":"HT1W-2EUX","price":162.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_ae6cbeb9-2aa6-49a0-aeb1-87d16eab11da.jpg?v=1772681407"},{"product_id":"senva-ht1w-2fud-humidity-sensor","title":"Senva HT1W-2FUD Surface Wall RH Sensor, 2% RH, LCD, 10K ohm Type 3 thermistor","description":"\u003cp\u003eThe Senva HT1W-2FUD is an HT1W surface-wall humidity sensor with the 2% RH accuracy option and an LCD display. In the shared HT1 ordering matrix, enclosure code W identifies surface-wall mounting, distinct from the HT1R recessed-wall version.\u003c\/p\u003e\u003cp\u003eThe selected temperature option is a 10K ohm Type 3 thermistor, a passive element rather than a temperature transmitter. Output code U selects universal analog output: 4-20 mA, 0-5 V, or 0-10 V, with 2-wire or 3-wire connection according to the selected mode and installation instructions.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148386025650,"sku":"HT1W-2FUD","price":182.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_54f98756-4e20-4509-bdc5-2a007beab10f.jpg?v=1772681408"},{"product_id":"senva-ht1w-2fux-humidity-sensor","title":"Senva HT1W-2FUX Surface Wall RH Sensor, 2% RH, No LCD, 10K ohm Type 3 thermistor","description":"\u003cp\u003eThe Senva HT1W-2FUX is an HT1W surface-wall humidity sensor with the 2% RH accuracy option and no LCD display. In the shared HT1 ordering matrix, enclosure code W identifies surface-wall mounting, distinct from the HT1R recessed-wall version.\u003c\/p\u003e\u003cp\u003eThe selected temperature option is a 10K ohm Type 3 thermistor, a passive element rather than a temperature transmitter. Output code U selects universal analog output: 4-20 mA, 0-5 V, or 0-10 V, with 2-wire or 3-wire connection according to the selected mode and installation instructions.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148386058418,"sku":"HT1W-2FUX","price":158.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_22339569-f396-4297-8ee3-13179ea3c4ce.jpg?v=1772681409"},{"product_id":"senva-ht1w-3aud-humidity-sensor","title":"Senva HT1W-3AUD Surface Wall RH Sensor, 3% RH, LCD","description":"\u003cp\u003eThe Senva HT1W-3AUD is an HT1W surface-wall humidity sensor with the 3% RH accuracy option and an LCD display. In the shared HT1 ordering matrix, enclosure code W identifies surface-wall mounting, distinct from the HT1R recessed-wall version.\u003c\/p\u003e\u003cp\u003eTemperature code A selects no optional temperature output. Output code U selects universal analog output: 4-20 mA, 0-5 V, or 0-10 V, with 2-wire or 3-wire connection according to the selected mode and installation instructions.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148386123954,"sku":"HT1W-3AUD","price":164.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_ccd094f3-0538-4718-9643-3cebf3ee543e.jpg?v=1772681411"},{"product_id":"senva-ht1w-3aux-humidity-sensor","title":"Senva HT1W-3AUX Surface Wall RH Sensor, 3% RH, No LCD","description":"\u003cp\u003eThe Senva HT1W-3AUX is an HT1W surface-wall humidity sensor with the 3% RH accuracy option and no LCD display. In the shared HT1 ordering matrix, enclosure code W identifies surface-wall mounting, distinct from the HT1R recessed-wall version.\u003c\/p\u003e\u003cp\u003eTemperature code A selects no optional temperature output. Output code U selects universal analog output: 4-20 mA, 0-5 V, or 0-10 V, with 2-wire or 3-wire connection according to the selected mode and installation instructions.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148386156722,"sku":"HT1W-3AUX","price":145.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_183ca95f-8321-4cec-863b-e4a681f8fd2e.jpg?v=1772681412"},{"product_id":"senva-ht1w-3bud-humidity-sensor","title":"Senva HT1W-3BUD Surface Wall RH Sensor, 3% RH, LCD, Temperature transmitter","description":"\u003cp\u003eThe Senva HT1W-3BUD is an HT1W surface-wall humidity sensor with the 3% RH accuracy option and an LCD display. In the shared HT1 ordering matrix, enclosure code W identifies surface-wall mounting, distinct from the HT1R recessed-wall version.\u003c\/p\u003e\u003cp\u003eTemperature code B selects a temperature transmitter. Output code U selects universal analog output: 4-20 mA, 0-5 V, or 0-10 V, with 2-wire or 3-wire connection according to the selected mode and installation instructions.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148386353330,"sku":"HT1W-3BUD","price":180.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_60db8e56-bf82-4f71-9249-e7cfed1a69f8.jpg?v=1772681413"},{"product_id":"senva-ht1w-3bux-humidity-sensor","title":"Senva HT1W-3BUX Surface Wall RH Sensor, 3% RH, No LCD, Temperature transmitter","description":"\u003cp\u003eThe Senva HT1W-3BUX is an HT1W surface-wall humidity sensor with the 3% RH accuracy option and no LCD display. In the shared HT1 ordering matrix, enclosure code W identifies surface-wall mounting, distinct from the HT1R recessed-wall version.\u003c\/p\u003e\u003cp\u003eTemperature code B selects a temperature transmitter. Output code U selects universal analog output: 4-20 mA, 0-5 V, or 0-10 V, with 2-wire or 3-wire connection according to the selected mode and installation instructions.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148386386098,"sku":"HT1W-3BUX","price":157.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_5d34dea0-be32-4ced-85e3-c68c6624ae9b.jpg?v=1772681415"},{"product_id":"senva-ht1w-3eud-humidity-sensor","title":"Senva HT1W-3EUD Surface Wall RH Sensor, 3% RH, LCD, 10K ohm Type 2 thermistor","description":"\u003cp\u003eThe Senva HT1W-3EUD is an HT1W surface-wall humidity sensor with the 3% RH accuracy option and an LCD display. In the shared HT1 ordering matrix, enclosure code W identifies surface-wall mounting, distinct from the HT1R recessed-wall version.\u003c\/p\u003e\u003cp\u003eThe selected temperature option is a 10K ohm Type 2 thermistor, a passive element rather than a temperature transmitter. Output code U selects universal analog output: 4-20 mA, 0-5 V, or 0-10 V, with 2-wire or 3-wire connection according to the selected mode and installation instructions.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148386582706,"sku":"HT1W-3EUD","price":178.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_599b2616-525c-42ce-a1e4-6a4039031247.jpg?v=1772681417"},{"product_id":"senva-ht1w-3eux-humidity-sensor","title":"Senva HT1W-3EUX Surface Wall RH Sensor, 3% RH, No LCD, 10K ohm Type 2 thermistor","description":"\u003cp\u003eThe Senva HT1W-3EUX is an HT1W surface-wall humidity sensor with the 3% RH accuracy option and no LCD display. In the shared HT1 ordering matrix, enclosure code W identifies surface-wall mounting, distinct from the HT1R recessed-wall version.\u003c\/p\u003e\u003cp\u003eThe selected temperature option is a 10K ohm Type 2 thermistor, a passive element rather than a temperature transmitter. Output code U selects universal analog output: 4-20 mA, 0-5 V, or 0-10 V, with 2-wire or 3-wire connection according to the selected mode and installation instructions.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148387631282,"sku":"HT1W-3EUX","price":157.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_7b1bcaba-5585-4e45-9923-26fe1860faa4.jpg?v=1772681420"},{"product_id":"senva-ht1w-3fud-humidity-sensor","title":"Senva HT1W-3FUD Surface Wall RH Sensor, 3% RH, LCD, 10K ohm Type 3 thermistor","description":"\u003cp\u003eThe Senva HT1W-3FUD is an HT1W surface-wall humidity sensor with the 3% RH accuracy option and an LCD display. In the shared HT1 ordering matrix, enclosure code W identifies surface-wall mounting, distinct from the HT1R recessed-wall version.\u003c\/p\u003e\u003cp\u003eThe selected temperature option is a 10K ohm Type 3 thermistor, a passive element rather than a temperature transmitter. Output code U selects universal analog output: 4-20 mA, 0-5 V, or 0-10 V, with 2-wire or 3-wire connection according to the selected mode and installation instructions.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148387664050,"sku":"HT1W-3FUD","price":181.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_c3c68c5d-3490-43fe-b57d-592c78d742ac.jpg?v=1772681422"},{"product_id":"senva-ht1w-3fux-humidity-sensor","title":"Senva HT1W-3FUX Surface Wall RH Sensor, 3% RH, No LCD, 10K ohm Type 3 thermistor","description":"\u003cp\u003eThe Senva HT1W-3FUX is an HT1W surface-wall humidity sensor with the 3% RH accuracy option and no LCD display. In the shared HT1 ordering matrix, enclosure code W identifies surface-wall mounting, distinct from the HT1R recessed-wall version.\u003c\/p\u003e\u003cp\u003eThe selected temperature option is a 10K ohm Type 3 thermistor, a passive element rather than a temperature transmitter. Output code U selects universal analog output: 4-20 mA, 0-5 V, or 0-10 V, with 2-wire or 3-wire connection according to the selected mode and installation instructions.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148387762354,"sku":"HT1W-3FUX","price":157.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_a8ea2b18-93b6-42de-9e7d-355ab06ce22a.jpg?v=1772681424"},{"product_id":"senva-ht1w-3kux-humidity-sensor","title":"Senva HT1W-3KUX Surface Wall RH Sensor, 3% RH, No LCD, 20K ohm thermistor","description":"\u003cp\u003eThe Senva HT1W-3KUX is an HT1W surface-wall humidity sensor with the 3% RH accuracy option and no LCD display. In the shared HT1 ordering matrix, enclosure code W identifies surface-wall mounting, distinct from the HT1R recessed-wall version.\u003c\/p\u003e\u003cp\u003eThe selected temperature option is a 20K ohm thermistor, a passive element rather than a temperature transmitter. Output code U selects universal analog output: 4-20 mA, 0-5 V, or 0-10 V, with 2-wire or 3-wire connection according to the selected mode and installation instructions.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148387893426,"sku":"HT1W-3KUX","price":157.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1R_Series_600x450_aebe1f4b-4561-4a57-b975-16c40b33437d.jpg?v=1772681425"},{"product_id":"senva-ht1o-2aud-humidity-sensor","title":"Senva HT1O-2AUD Outdoor RH Sensor, 2% RH, LCD","description":"\u003cp\u003eThe Senva HT1O-2AUD is an HT1O outdoor humidity sensor with +\/-2% RH specified accuracy over 0-100% RH and an LCD display. No optional temperature output is selected; internal temperature compensation for RH does not add a temperature output.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. Voltage-mode supply is 12-30 VDC or 24 VAC, 15 mA maximum; 2-wire current mode uses 12-30 VDC, 30 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The outdoor design includes a gasketed lid, sintered stainless-steel media filter, and field-replaceable sensing element.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148387958962,"sku":"HT1O-2AUD","price":171.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1O_Series_98eac78a-6cb1-4f4b-9f0c-01d8b7e5f81b.jpg?v=1772681427"},{"product_id":"senva-ht1o-2aux-humidity-sensor","title":"Senva HT1O-2AUX Outdoor RH Sensor, 2% RH, No LCD","description":"\u003cp\u003eThe Senva HT1O-2AUX is an HT1O outdoor humidity sensor with +\/-2% RH specified accuracy over 0-100% RH and no LCD display. No optional temperature output is selected; internal temperature compensation for RH does not add a temperature output.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. Voltage-mode supply is 12-30 VDC or 24 VAC, 15 mA maximum; 2-wire current mode uses 12-30 VDC, 30 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The outdoor design includes a gasketed lid, sintered stainless-steel media filter, and field-replaceable sensing element.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148388057266,"sku":"HT1O-2AUX","price":165.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1O_Series_a52baab6-f3e6-47e3-921d-66ecf80c100f.jpg?v=1772681428"},{"product_id":"senva-ht1o-2bud-humidity-sensor","title":"Senva HT1O-2BUD Outdoor RH Sensor, 2% RH, LCD, Temperature transmitter","description":"\u003cp\u003eThe Senva HT1O-2BUD is an HT1O outdoor humidity sensor with +\/-2% RH specified accuracy over 0-100% RH and an LCD display. This configuration includes a temperature transmitter with selectable 0-50 degrees C or -40 to 60 degrees C output scaling. Output scaling is not an overall operating-temperature rating.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. Voltage-mode supply is 12-30 VDC or 24 VAC, 15 mA maximum; 2-wire current mode uses 12-30 VDC, 30 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The outdoor design includes a gasketed lid, sintered stainless-steel media filter, and field-replaceable sensing element.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148388122802,"sku":"HT1O-2BUD","price":177.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1O_Series_25d5be0a-5ebd-4645-a923-1aff2ab671c6.jpg?v=1772681429"},{"product_id":"senva-ht1o-2bux-humidity-sensor","title":"Senva HT1O-2BUX Outdoor RH Sensor, 2% RH, No LCD, Temperature transmitter","description":"\u003cp\u003eThe Senva HT1O-2BUX is an HT1O outdoor humidity sensor with +\/-2% RH specified accuracy over 0-100% RH and no LCD display. This configuration includes a temperature transmitter with selectable 0-50 degrees C or -40 to 60 degrees C output scaling. Output scaling is not an overall operating-temperature rating.\u003c\/p\u003e\u003cp\u003eThe U universal output supports selectable 0-5 V, 0-10 V, or 4-20 mA, with 2-wire and 3-wire modes as specified in the installation instructions. RH output scaling is 0-100% RH, non-condensing. The 0-10 V output requires 15-30 VDC or 24 VAC. Voltage-mode supply is 12-30 VDC or 24 VAC, 15 mA maximum; 2-wire current mode uses 12-30 VDC, 30 mA maximum.\u003c\/p\u003e\u003cp\u003eOn-board temperature compensation supports RH measurement. The RH element normal operating conditions are 5-60 degrees C at 20-80% RH; prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. No NIST calibration option is selected in this part number. The outdoor design includes a gasketed lid, sintered stainless-steel media filter, and field-replaceable sensing element.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148388253874,"sku":"HT1O-2BUX","price":180.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT1O_Series_43ae8c4b-dfc4-48fb-a0a5-a590281076ae.jpg?v=1772681430"},{"product_id":"senva-ht0r-2aa-humidity-sensor","title":"Senva HT0R-2AA Recessed Wall RH Sensor, 2% RH, 0-5 V, 3-wire","description":"\u003cp\u003eThe Senva HT0R-2AA is an HT0R recessed-wall humidity sensor with +\/-2% RH maximum specified accuracy over 0-100% RH and a 0-5 V, 3-wire RH output. No optional temperature output is selected. The output type and wiring are specific to this ordering code; this is not a universal-output model.\u003c\/p\u003e\u003cp\u003eRH output scaling is 0-100% RH, non-condensing. On-board temperature compensation supports RH measurement but does not add a temperature-transmitter output. The slim, tamper-resistant housing has no exposed screws, fits standard single-gang boxes, and includes a gasket to seal the sensing element against wall drafts.\u003c\/p\u003e\u003cp\u003eThe enclosure is rated IP20\/NEMA 1. The PTFE media filter has IP54 protection; that is not the enclosure rating. Normal RH operating conditions are 5-60 degrees C at 20-80% RH. Prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148388384946,"sku":"HT0R-2AA","price":105.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT0R_Series_95a28417-2608-4f0b-9d88-a3024df23b94.jpg?v=1772681432"},{"product_id":"senva-ht0r-2ac-humidity-sensor","title":"Senva HT0R-2AC Recessed Wall RH Sensor, 2% RH, 0-5 V, 3-wire, 100 ohm platinum RTD","description":"\u003cp\u003eThe Senva HT0R-2AC is an HT0R recessed-wall humidity sensor with +\/-2% RH maximum specified accuracy over 0-100% RH and a 0-5 V, 3-wire RH output. This configuration includes a 100 ohm platinum RTD as a separate passive temperature option, not a temperature transmitter. The output type and wiring are specific to this ordering code; this is not a universal-output model.\u003c\/p\u003e\u003cp\u003eRH output scaling is 0-100% RH, non-condensing. On-board temperature compensation supports RH measurement but does not add a temperature-transmitter output. The slim, tamper-resistant housing has no exposed screws, fits standard single-gang boxes, and includes a gasket to seal the sensing element against wall drafts.\u003c\/p\u003e\u003cp\u003eThe enclosure is rated IP20\/NEMA 1. The PTFE media filter has IP54 protection; that is not the enclosure rating. Normal RH operating conditions are 5-60 degrees C at 20-80% RH. Prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148388450482,"sku":"HT0R-2AC","price":114.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT0R_Series_d2645edc-fa10-4323-9e2f-132699574032.jpg?v=1772681433"},{"product_id":"senva-ht0r-2ad-humidity-sensor","title":"Senva HT0R-2AD Recessed Wall RH Sensor, 2% RH, 0-5 V, 3-wire, 1000 ohm platinum RTD","description":"\u003cp\u003eThe Senva HT0R-2AD is an HT0R recessed-wall humidity sensor with +\/-2% RH maximum specified accuracy over 0-100% RH and a 0-5 V, 3-wire RH output. This configuration includes a 1000 ohm platinum RTD as a separate passive temperature option, not a temperature transmitter. The output type and wiring are specific to this ordering code; this is not a universal-output model.\u003c\/p\u003e\u003cp\u003eRH output scaling is 0-100% RH, non-condensing. On-board temperature compensation supports RH measurement but does not add a temperature-transmitter output. The slim, tamper-resistant housing has no exposed screws, fits standard single-gang boxes, and includes a gasket to seal the sensing element against wall drafts.\u003c\/p\u003e\u003cp\u003eThe enclosure is rated IP20\/NEMA 1. The PTFE media filter has IP54 protection; that is not the enclosure rating. Normal RH operating conditions are 5-60 degrees C at 20-80% RH. Prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148388548786,"sku":"HT0R-2AD","price":114.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT0R_Series_2bb3b9bc-6519-474e-8091-2f649389df5e.jpg?v=1772681434"},{"product_id":"senva-ht0r-2ae-humidity-sensor","title":"Senva HT0R-2AE Recessed Wall RH Sensor, 2% RH, 0-5 V, 3-wire, 10K ohm Type 2 thermistor","description":"\u003cp\u003eThe Senva HT0R-2AE is an HT0R recessed-wall humidity sensor with +\/-2% RH maximum specified accuracy over 0-100% RH and a 0-5 V, 3-wire RH output. This configuration includes a 10K ohm Type 2 thermistor as a separate passive temperature option, not a temperature transmitter. The output type and wiring are specific to this ordering code; this is not a universal-output model.\u003c\/p\u003e\u003cp\u003eRH output scaling is 0-100% RH, non-condensing. On-board temperature compensation supports RH measurement but does not add a temperature-transmitter output. The slim, tamper-resistant housing has no exposed screws, fits standard single-gang boxes, and includes a gasket to seal the sensing element against wall drafts.\u003c\/p\u003e\u003cp\u003eThe enclosure is rated IP20\/NEMA 1. The PTFE media filter has IP54 protection; that is not the enclosure rating. Normal RH operating conditions are 5-60 degrees C at 20-80% RH. Prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148388614322,"sku":"HT0R-2AE","price":114.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT0R_Series_cac66ec8-bac8-4a5b-921b-eccd08d23b38.jpg?v=1772681435"},{"product_id":"senva-ht0r-2af-humidity-sensor","title":"Senva HT0R-2AF Recessed Wall RH Sensor, 2% RH, 0-5 V, 3-wire, 10K ohm Type 3 thermistor","description":"\u003cp\u003eThe Senva HT0R-2AF is an HT0R recessed-wall humidity sensor with +\/-2% RH maximum specified accuracy over 0-100% RH and a 0-5 V, 3-wire RH output. This configuration includes a 10K ohm Type 3 thermistor as a separate passive temperature option, not a temperature transmitter. The output type and wiring are specific to this ordering code; this is not a universal-output model.\u003c\/p\u003e\u003cp\u003eRH output scaling is 0-100% RH, non-condensing. On-board temperature compensation supports RH measurement but does not add a temperature-transmitter output. The slim, tamper-resistant housing has no exposed screws, fits standard single-gang boxes, and includes a gasket to seal the sensing element against wall drafts.\u003c\/p\u003e\u003cp\u003eThe enclosure is rated IP20\/NEMA 1. The PTFE media filter has IP54 protection; that is not the enclosure rating. Normal RH operating conditions are 5-60 degrees C at 20-80% RH. Prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148388745394,"sku":"HT0R-2AF","price":114.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT0R_Series_006058b5-2b80-44bf-9edc-375ead36f897.jpg?v=1772681436"},{"product_id":"senva-ht0r-2ba-humidity-sensor","title":"Senva HT0R-2BA Recessed Wall RH Sensor, 2% RH, 0-10 V, 3-wire","description":"\u003cp\u003eThe Senva HT0R-2BA is an HT0R recessed-wall humidity sensor with +\/-2% RH maximum specified accuracy over 0-100% RH and a 0-10 V, 3-wire RH output. No optional temperature output is selected. The output type and wiring are specific to this ordering code; this is not a universal-output model.\u003c\/p\u003e\u003cp\u003eRH output scaling is 0-100% RH, non-condensing. On-board temperature compensation supports RH measurement but does not add a temperature-transmitter output. The slim, tamper-resistant housing has no exposed screws, fits standard single-gang boxes, and includes a gasket to seal the sensing element against wall drafts.\u003c\/p\u003e\u003cp\u003eThe enclosure is rated IP20\/NEMA 1. The PTFE media filter has IP54 protection; that is not the enclosure rating. Normal RH operating conditions are 5-60 degrees C at 20-80% RH. Prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. The 0-10 V output requires 15-30 VDC or 24 VAC.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148388810930,"sku":"HT0R-2BA","price":105.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT0R_Series_1386902d-1ade-45ec-a12e-27d561127ad7.jpg?v=1772681438"},{"product_id":"senva-ht0r-2bc-humidity-sensor","title":"Senva HT0R-2BC Recessed Wall RH Sensor, 2% RH, 0-10 V, 3-wire, 100 ohm platinum RTD","description":"\u003cp\u003eThe Senva HT0R-2BC is an HT0R recessed-wall humidity sensor with +\/-2% RH maximum specified accuracy over 0-100% RH and a 0-10 V, 3-wire RH output. This configuration includes a 100 ohm platinum RTD as a separate passive temperature option, not a temperature transmitter. The output type and wiring are specific to this ordering code; this is not a universal-output model.\u003c\/p\u003e\u003cp\u003eRH output scaling is 0-100% RH, non-condensing. On-board temperature compensation supports RH measurement but does not add a temperature-transmitter output. The slim, tamper-resistant housing has no exposed screws, fits standard single-gang boxes, and includes a gasket to seal the sensing element against wall drafts.\u003c\/p\u003e\u003cp\u003eThe enclosure is rated IP20\/NEMA 1. The PTFE media filter has IP54 protection; that is not the enclosure rating. Normal RH operating conditions are 5-60 degrees C at 20-80% RH. Prolonged exposure to high humidity outside normal conditions may temporarily offset RH readings. The 0-10 V output requires 15-30 VDC or 24 VAC.\u003c\/p\u003e","brand":"Senva","offers":[{"title":"Default Title","offer_id":47148388909234,"sku":"HT0R-2BC","price":114.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/files\/HT0R_Series_3be3357e-0a94-4ba2-81d1-5edc9074ea4f.jpg?v=1772681439"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6640\/7602\/collections\/HUMIDITY.jpg?v=1768004283","url":"https:\/\/e-controls.net\/collections\/humidity-control.oembed?page=16","provider":"E-Controls.net","version":"1.0","type":"link"}